The. For different configurations, see, Wattmeter (instantaneous power expressed in kW) (note 1), Wattmeter (Power consuption expressed in kWh/h) (note 2), Absolute worked time (expressed in days) (note 3), Absolute worked time (expressed in hours) (note 3), Notes: 1. Input impedance: > 1 MW for mV Input 500 kW for Volt Input. On burnout, it will be 0 mA. High Quality SDA25x30 Pneumatic SDA25-30mm Double Acting Compact AIR any latin characters (a-z, A-Z) any numbers (0-9) special characters ("-", "_" and ". Yokogawa TC10-L Brochure - manualmachine.com The shallow depth of the controller helps to save instrument panel space. Notes: 1. the controller use can be found in the Engineering Manual: IM 05C01E81-02EN and the Communication Manual: IM 05C01E81-03EN. 1 digit @ 25C of room temperature; Electromagnetic compatibility and safety requirements. To load the factory default parameter set, proceed as follows: 1.Press the button for more than 5 seconds. No. (100 to 240 VAC), Insulation voltage: 2300 V rms according to EN 61010-1, Front protection: IP 65 (when the optional panel gasket is mounted), Accessories: Mounting bracket, Quick Guide, Operative Modes: Auto / Manual / Stand-by (force control output to zero), Serial Communication (optional): RS-485 MODBUS, PID control with single or double action with overshoot control (Fuzzy overshoot control), ON/OFF, ON/OFF Neutral Zone, Auto-tuning, and Self-tuning. Model: TC10-L Quick Guide . There's no SG terminal for wiring RS485 communication on the TC1. YOKOGAWA TC10 Engineering Manual | Manualzz . 1. The Yokogawa TC10 is a compact,all-in-one, single loop temperature controller with an easy-to-read, 3-color LED display. 1 to 4 indicate the status of outputs 1 to 4. can be downloaded (free of charge) from the web-site: The Authorised Representative for this product in the EEA is: Yokogawa Europe BV (Address: Euroweg 2 , 3825 HD Amersfoort, The Netherlands) is the Authorised Representative of. condensation); 5. The UT32A-V,-C,-R is an easily configurable single-loop controller for 1/8 DIN sized. US $17.58. Allows to increase the value of the selected parameter. switch is a device for turning off the power to the instrument. TC10-L Temperature Limit Controller - Yokogawa - Weschler Instruments The access to the conguration parameters is protected by a password. Approximately 2 seconds or less. Notes: 1. condensation); 5. 600W. The UT35A and UT32A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. Notes: 1. Can I use the DI function to switch between auto/manual and between run stop/start? Select a mounting location having the following characteristics: 2. equipment and devices that ensure personnel safety. and General Specification: GS 05C01E81-11EN. Case: Plastic, self-extinguishing degree: V-0 according to UL 94, Front protection: IP 65 (when the optional panel gasket is mounted) for indoor locations according to EN 60070-1, Terminals protection: IP 20 according to EN 60070-1, Terminal block: 16 screw terminals for cables of 0.25 to 2.5 mm2 (AWG22 to AWG14) with connection diagram, tightening torque 0.5 Nm, Dimensions: 48 x 48, depth 62 mm (1.89 x 1.89 x 2.87 in. A ladder sequence function is included as standard. 2.56 in min. Yokogawa TC10-L Manual The conguration procedure allows to take advantage of all instrument features. TC10-L is capable of a retransmission . AL on the front of the TC10 is the alarm lamp. When you do this, the upper limit range of 1000C becomes 999.9C. - This product is intended to be handled by skilled/trained person-, - This instrument is for Measurement Category No. Can't find your region? Download Manual of YOKOGAWA TC 10-L Controller for Free or View it Online on All-Guides.com. YOKOGAWA TC 10-L Controller Manual PDF View/Download Do not use it, for measurements in locations falling under Measurement Catego-, For measurements performed on circuits not directly, For measurements performed on circuits directly. The shallow depth of the controller helps save to space. voltage contact between terminals 4 and 16; - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. period. the protection provided by this instrument may be impaired. The ambient temperature is in accordance with the operative, 6. Controller YOKOGAWA TC 10-L Engineering Manual, Controller YOKOGAWA UT350 Instruction Manual, Controller YOKOGAWA FX103 User Manual, Controller YOKOGAWA UT32A User Manual, Controller YOKOGAWA UTAdvanced UT35A Technical Information. Do I need a minus sign ( - ) on the alarm setting value? Worked Time counter is continuously increased when, Overall dimensions (L x H x D): 48 x 48 x 73 mm, This instrument is intended for permanent installation, for indoor. Burn out: full scale Calibration:According to EN 60584-1. If so used, it is the user's responsibility to include in the system additional. countries or regions where wiring will be installed. The default data are those typical values loaded in the instrument prior to ship it from factory. Are the TC10s wiring terminals screw terminals? Yokogawa TC10 Temperature Controller Starting at $203.00 Select Options and Add to Cart View Company Reviews Manufactured By Yokogawa Includes FREE Ground Shipping on orders of $1,000 or more FREE Lifetime Tech Support Availability Usually ships in 2-3 weeks Product Manual Product Specs Overview Description Documents Accessories Features the controller use can be found in the Engineering Manual: IM 05C01E81-02EN and the Communication Manual: IM 05C01E81-03EN. Pt 1000 calibration: According to EN 60751/A2. Do not use it, for measurements in locations falling under Measurement Catego-, For measurements performed on circuits not directly, For measurements performed on circuits directly. Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. 16 AWG or larger wires rated for at last 75C. A reinforced isolation must be assured by the external solid state relays. For complete controller configuration see the Engineering Manual. When the instrument is powered, it starts immediately to work according to the parameters values loaded in its memory. When the maximum front protection (IP65) is. SSc allows the scaling of the analog input to set the minimum displayed/measured value. Moreover, provide indication that the. 5, the lower display is showing its value, this key allows, to store the selected value for the current parameter. Also, YOKOGAWA Electric Corporation assumes no liability for the customer's, failure to comply with these requirements. CONTROLLER Engineering Manual. PDF TC 10 - L 1.3 MOUNTING REQUIREMENTS TC10 - Yokogawa The Yokogawa TC10-L is an all-in-one, FM approved limit controller with an easy-to-read, 3-color LED display. Download YOKOGAWA TC10-L Quick Manual | ManualsLib The relative humidity is in accordance with the instrument. The UT52A/MDL supports 920 MHz band wireless communication. 1. View and Download Yokogawa UT55A instruction manual online. With thermocouple K input, can I display digits after the decimal point for the temperature? There are no water or other fluids (i.e. Yokogawa Electric Corporation - TC10 - ENGINEERING MANUAL - PAG. 2.56 in min. The TC10 supports easy configuration with codes for quick start-up. We assume no liability for safety, or responsibility for, the product's quality, performance or functionality should users. A ladder sequence function is included as standard. If applicable, a timer count control monitors the amount of time outside the setpoint and registers the maximum temperature reached. countries or regions where wiring will be installed. switch is a device for turning off the power to the instrument. Features 3 Dynamic Colors Led Display Compact size: 48 x 48 mm (1/16 DIN), depth 48 mm All information about the controller use can be found in the Engineering Manual: IM 05C01E81-02EN and the Communication Manual: IM 05C01E81-03EN and General Specification: GS 05C01E81-01EN. 3. IM 05C01E81-01EN 1 Edition Oct. 2014 st Yokogawa Electric Corporation 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan internet site: www.yokogawa.com/ns Declaration of conformity and Manual retrieval TC10 is a panel mounting, Class II instrument. Controller YOKOGAWA TC 10-L Engineering Manual 20 pages. The TC10 supports easy configuration with codes for quick start-up. TC10 is a panel mounting, Class II instrument. OUTLINE DIMENSIONS (mm) 1.1 INSTRUMENT DIMENSIONS 48 PV Optional gasket 1.2 PANEL CUT-OUT 45 +0.6 mm 1.78 +0.023 YOKOGAWA TC10 TEMPERATURE CONTROLLER ENGINEERING MANUAL | ManualsLib Every group denes all parameters related with a specic function (e.g. There is minimum vibrations and no impact; 4. The conguration parameters are collected in various groups. PDF Model TC10 Temperature Controller, Engineering Manual - Weschler It has been designed with compliance to the European Directives. At this point the instrument restarts as for a new power ON. 0.25 to 2.5 mm2 (AWG22 to AWG14) with connection diagram, tightening torque 0.5 Nm; Dimensions: 48 x 48, depth 73 mm, (1.89 x 1.89 x 2.87 in. The UT32A-V,-C,-R is an easily configurable single-loop controller for 1/8 DIN sized. All information about the controller use can be found in the Engineering Manual: IM 05C01E81-12EN and the Communication Manual: IM 05C01E81-13EN and General Specification: GS 05C01E81-11EN. Looking for more information on our people, technology and solutions? The ambient temperature is in accordance with the operative, 6. 1 to 4 indicate the status of outputs 1 to 4. {{ baseCtrl.fullNavList[baseCtrl.fullNavList[baseCtrl.currentMenuDepth].parent].name }}, {{ baseCtrl.fullNavList[baseCtrl.currentMenuDepth].name }}, Special Solutions of OpreX Transformation, Visual MESA Supply Chain Scheduling (VM-SCS), Visual MESA Production Accounting (VM-PA), Cloud Inventory Management Solutions (Web*VMI), Platform for Advanced Control and Estimation (Advanced Process Control), OpreX Laboratory Information Management System, Remote Plant Performance Operation and Remote Consulting (KBC Co-Pilot Program), Predictive Maintenance of Pump Cavitation, Advanced Analytical Instrument Management System (AMADAS), FluidCom Chemical Injection Flow Controller, Real-time Plant Data Sharing Service (Web*Technician), Digital Plant Operation Intelligence (DPI) Quality Stabilization System, OpreX Data Model Broker / Design Data Validation, OpreX Customer Service Management Software, OpreX IT/OT Security Operations Center (SOC), Plant Information Management System (Exaquantum), Alarm Reporting and Analytics (Exaquantum/ARA), Integrated Production Information (Exaquantum/mPower), Power Performance Calculations (Exaquantum/PPC), Safety Function Monitoring (Exaquantum/SFM), Operator Trending Module (Exaquantum/OTM), Remote Data Synchronization (Exaquantum/RDS), Synchronous OPC DA Manager (Exaquantum/SDM), Manufacturing Data Exchange (Exaquantum/MDX), Public announcement of Yokogawas products, Single-Cell Analysis Solution Single Cellome, Distributed Temperature Sensor - Fire Detection/Fire Prevention -, Industry and Interface Libraries (Applications and Interfaces), Advanced Control Bioreactor System BR1000, ALH for FlowCam: Automated Liquid Handling, Yokogawa announcement to Windows XP users regarding Systems products, A Business Value Decision ofImpact and Significance, Yokogawa Cloud IT/OT Connectors & Integrations, Support InformationNew Legislative Framework (NLF) Conforming Products, Temperature Control for Seal-heating Parts in Wrapping Machinery. TC10-L is a panel mounting, Class II instrument. YOKOGAWA Accessory Manuals 12 Devices / 14 Documents Full list of YOKOGAWA Accessory Manuals YOKOGAWA AC Power Distribution Manuals 1 Devices / 1 Documents YOKOGAWA Adapter Manuals 9 Devices / 10 Documents TC10. The output (OUT) display lamp is lit. and workmanship for 18 months from the date of manufacturing. Safety, Protection, and Modification of the Product, - In order to protect the system controlled by this product and the, product itself, and to ensure safe operation, observe the safety, precautions described in the Engineering manual. We assume no liability for safety, or responsibility for the, product's quality, performance or functionality should users fail to. The following general safety precautions must be observed during. Limit control type. IP65 rated as "dust tight" and protected against water projected from a nozzle when the optional panel gasket is mounted (for indoor locations) according to EN 60070-1. Model TC10 Temperature Controller, Quick Guide, Model TC10 Temperature Controller, Engineering Manual, Model TC10 Temperature Controller, Serial communication protocol Modbus for TC10, New Legislative Framework (NLF) Conforming Products, List of RoHS (2011/65/EU) Directive Compliant Products (6-substances RoHS compliant products), Replacement Guide for TC10 Temperature Controller, The EU Declaration of Conformity TC10 *Log-in Required, Temperature Controllers 2D CAD *Log-in Required, Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals), Universal input: (TC, mV, V, mA, Pt100-Pt1000), IP65 front panel (when the optional panel gasket is mounted)(optional). that no power is being supplied to a cable to be connected. Do I need a minus sign ( - ) on the alarm setting value? Do not run logic input wiring together with power cables; The instrument needs 150 ms to recognize a contact status variation; To avoid electrical shocks, connect power line at last. The relative humidity is in accordance with the instrument, The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the optional, - Digital Input (DI2) connecting a free of. 18 months (a year and a half) after shipment from the factory. TC10-L Limit Controller | Yokogawa America All information about. TC10-Ls compact design allows for a broad range of applications/uses while maintaining a high level of accuracy. The TC10-L features universal input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to . 18 months (a year and a half) after shipment from the factory. View online Manual for YOKOGAWA TC 10-L Controller or simply click Download button to examine the YOKOGAWA TC 10-L guidelines offline on your desktop or laptop computer. Model: TC10 Digital Indicating Controller with one universal input, one control output, and one selectable I/O. The short depth of the controller helps save instrument panel space. 2. (limit control type) (150 pages), Programmable /indicating controller (96 pages), Digital indicating controller (108 pages), Digital indicating controllers (109 pages), Manual will be automatically added to "My Manuals", Controller YOKOGAWA TC 10-L Engineering Manual, Controller YOKOGAWA UT350 Instruction Manual, Controller YOKOGAWA UTAdvanced UT35A Technical Information, Controller YOKOGAWA Fluidcom S2 User Manual, Controller YOKOGAWA UT35A Operation Manual, Controller YOKOGAWA UT32A-R Operation Manual, Controller YOKOGAWA YS1000 Series User Manual, Controller Yokogawa FA-M3 System Upgrade Manual, Controller YOKOGAWA UT750 Instruction Manual. Click here to select options, We're open Mo-Th 8am to 5:30pm. Yokogawa TC10-L Limit Controller | Temperature Controllers - Instrumart exposed terminals and wiring on the back. 2.It is possible to set a initial scale read-out higher than the full scale read-out in order to obtain a reverse read-out scaling. The TC10 supports easy configuration for quick start-up, and itsPID allows for overshoot andundershoot control, so the end user can maintain a direct and constant temperature or accurate flow. connected to the low-voltage installation. It has been designed, with compliance to the European Directives. SSR outputs are not isolated. The EU Declaration of Conformity and the manual of the controller. 1. Supply Voltage: 100 to 240 VAC (-15 to +10%). The input resolution specification the TC10 is 30000. Search the full list . Select a mounting location having the following characteristics: 2. Main Features Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals) 3 Dynamic Colors Led Display Universal input: (TC, mV, V, mA, Pt100-Pt1000) 4 Set Points and alarm functions Serial communication : RS-485 Modbus PID control, ON/OFF, Auto-tuning Also, YOKOGAWA Electric Corporation assumes no liability for the custo-, mer's failure to comply with these requirements. The TC series of temperature controllers is perfect for controlling the heating temperature of sealing parts and the temperature of sealing rolls (pre-heating) in a variety of different wrapping machinery. rear housing, exposed terminals and wiring on the back. Worked Time counter is continuously increased when, Overall dimensions (L x H x D): 48 x 48 x 73 mm, This instrument is intended for permanent installation, for indoor. SSR outputs are not isolated. The instrument have one complete parameter set. Allows to decrease the value of the selected parameter. : control, alarms, output functions). I'm looking for a replacement for the UD310. Use a tester or similar device to ensure. Products and components that are subject to wear due to conditions. be downloaded (free of charge) from the web-site: The Authorised Representative for this product in the EEA is: Viale Indipendenza 56, 27029 Vigevano (PV) - ITALY, The following general safety precautions must be observed during. If this instrument is used in a manner not specified in this manual. Yokogawa TC10-L Limit Controller Starting at $329.00 Select Options and Add to Cart View Company Reviews Manufactured By Yokogawa Includes FREE Ground Shipping on orders of $1,000 or more FREE Lifetime Tech Support Availability Some models in stock. Yokogawa TC10 Manual Download for 1 TC10 TEMPERATURE CONTROLLER Engineering Manual Code: IM 05C01E81-02EN Third edition: Feb. 2018 Yokogawa Electric Corporation 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan www.yokogawa.com/ns 1. Installation altitude: less than 2000 m; The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the optional, - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. - This product is intended to be handled by skilled/trained person-, - This instrument is for Measurement Category No. On the TC10, I want the difference lower limit alarm to be ON 5C below the setpoint value. of use, service life and misuse are not covered by this warranty. At the rst start up the instrument will use a default parameter set (factory parameter set); this set is a generic one (e.g. In the following pages we will describe all the parameters of the instrument. View available part numbers. The output relay is always de-energized (opened) at poweron,even if PV does not exceed SP(A). For supply connections use No. The TC10-L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user. setting AL1t [Alarm 1 type] to nonE [not used], all parameters related to alarm 1 will be skipped). Product Manual Product Specs Overview Description Documents In Stock Can it output the SP setting value? values and the controller output instantaneous value. Yokogawa TC10-L Temperature Controller Datasheet PDF, Yokogawa TC10-L Limit Controller Quick Reference Guide, Yokogawa TC10-L Temperature Controller Manual PDF, Yokogawa TC10-L Temperature Controller Brochure PDF, Yokogawa UT150L to TC10-L Cross Reference Guide PDF, Universal Input: (TC, mV, V, mA, Pt100-Pt1000), Limit control function (High limit / Low limit), Includes one digital input for external limit reset. and General Specification: GS 05C01E81-01EN. A short press allows to exit from the current parameter group and select a new parameter group. The 3-year warranty extends 36 months after shipment from our factory. Clamp meters use wide jaws that clamp around the outside of an electrical conductor to provide non-contact current measurements. switch is a device for turning off the power to the instrument. IP65 rated as "dust tight" and protected against water projected from a nozzle when the optional panel gasket is mounted (for indoor locations) according to EN 60070-1. For measurements performed in the building instal-, For measurements performed at the source of the, - Wiring work must be carried out by a person with basic electrical, - Be sure to turn OFF the power supply to the controller before wiring, to avoid an electric shock. External resistance: 100W max., maximum error 25 V. Cold junction: automatic compensation between 0 to 55C. Wattmeter Instantaneous power is continuously computed, as multiplication of the Load Voltage, Load Current parameter. Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. digitalview ALR-1400 Controller Instructions manual PDF View/Download TC10s compact design allows for a broad range of applications/uses while maintaining a high level of accuracy. Other part numbers are available to order but are not currently in stock. PDF Model TC10 Temperature Controller, Engineering Manual - Instrumart The Yokogawa TC10 is a compact, all-in-one, single loop temperature controller with an easy-to-read, 3-color LED display. 2.External components (like zener barriers, etc.) Moreover, provide indication that the. Case: Plastic, self-extinguishing degree: V-0 according to UL 94; Front protection: IP 65 (when the optional panel gasket is mounted) for indoor locations according to EN 60070-1; Terminals protection: IP 20 according to EN 60070-1; Terminal block: 16 screw terminals for cables of. Every change of the SEnS parameter will produces a change of the related parameter and in particular: [11] Ao1L and [12] Ao1H (when the analog retransmission is present) will be forced to the Ex.Range limits. I selected SP value transmission on TC10, but no SP value is displayed. I want to use the detailed parameter setting method of TC10, but what number is the password? These meters commonly measure voltage, resistance, continuity, capacitance, and more. - As a safety measure, always install a circuit breaker (an IEC 60947, compatible product, 5 A, 100 V or 220 V AC) in an easily accessible, location near the instrument. Yokogawa Electric Corporation for this Product in the EEA. connected to the low-voltage installation. Only wire the other instruments SG terminal. Available: When a linear input is selected by [1] SenS. The UT55A/UT52A also support open networks such as Ethernet communication. "), 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan www.yokogawa.com/ns. 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan, Yokogawa Electric Corporation - TC10 - ENGINEERING MANUAL - PAG. It has been de-, signed with compliance to the European Directives. When installing the TC10, what is the depth in millimeters from the surface of the panel? The UT55A and UT52A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. Input impedance:> 1 M. 3 2.3 OUTPUTS Safety notes: - To avoid electrical shocks, connect power line at last. equipment and devices that ensure personnel safety. PDF TC10 Temperature Controller - Yokogawa Approximately 2 seconds or less. SSR outputs are not isolated. Products and components that are subject to wear due to conditions. when you re-congure an instrument previously used for other works or from other people or when you have made too many errors during conguration and you decided to re-congure the instrument, it is possible to restore the factory conguration. If the other instruments have an SG terminal, how should I wire it? terminal 1 and 2 to transmitter signal output. IP65 Certification when the optional panel gasket is mounted. Model: TC10 - Quick Guide . RS-485 interface allows to connect up to 30 devices with one remote master unit. IM 05C01E81-01EN, 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan, EU Declaration of conformity and Manual retrieval, TC10 is a panel mounting, Class II instrument. - Installation of protection and/or safety circuits with respect to a, lightning protector; protective equipment for the system controlled, by the product and the product itself; foolproof or failsafe design, of a process or line using the system controlled by the product or, the product itself; and/or the design and installation of other, protective and safety circuits are to be appropriately implemented, Note: To leave the Configuration session without, - This product is not designed or manufactured to be used in critical, applications that directly affect or threaten human lives.
Is Byrna Legal In Canada, Articles Y